登录 | 注册    关注公众号  
微信公众号
搜索
 >  Kits>Spike RBD >FCM-B02R

Mouse SARS-CoV-2 Variants Total IgG 6-plex Panel (Flow Cytometry Multiplex Bead Assay)

For research use only.

产品描述(Product Details)

Assay Type FACS
Analyte Wild-type
Alpha B.1.1.7
Beta B.1.351
Gamma P.1
Delta B.1.617.2
Omicron B.1.1.529
Format 96T
Reactivity Mouse
Regulatory Status RUO
Sensitivity 1.50 ng/mL
4.40 ng/mL
2.62 ng/mL
1.88 ng/mL
2.11 ng/mL
1.03 ng/mL
Standard Curve Range 16.25~1040 ng/mL
Assay Time 1 hr 50 min
Suitable Sample Type mouse serum, mouse plasma
Sample volume 3 μL

组分(Materials Provided)

ID Components Size
FCM02-C01 SARS-CoV-2 Antibody Calibrator 20μg
FCM02-C02 RBD 6-plex Beads 200μL
FCM02-C03 Assay Buffer 40mL×2
FCM02-C04 5 × Wash Buffer 10mL
FCM02-C05 PE-Labeled Anti-mouse IgG Detection Antibody 50μL
FCM02-C06 5 × PBS Buffer 10mL
FCM02-C07 APC Beads 500μL
FCM02-C08 PE Beads 500μL
FCM02-C09 96-Well V-bottom Plate 1plate
FCM02-C10 96-Well Sealing Film 2pieces

背景(Background)

Since December 2019, the emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and its associated disease, COVID-19, has caused a devastating pandemic worldwide.As the virus spreads globally, the continuous emergence of new mutant strains escalated the challenge on humans.To facilitate the mutant-related research, drug trials and vaccine development, a multiplex serological test for assessing antibody responses to mutant strains is in urgent need.

应用说明(Application)

The kit is developed for qualitative detection of Anti-SARS-CoV-2 Variants (Alpha, Beta, Gamma, Delta, Omicron) total IgG antibody in mouse serum.

It is for research use only.

存储(Storage)

1. Unopened kit should be stored at 2℃-8℃ upon receiving.
2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.
3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

原理(Assay Principles)

SARS-CoV-2 Variants Total IgG 6-plex Panel is a multiplex bead-based indirect immunofluorescence assay, utilizing flow cytometry for data acquisition and classification. Six SARS-CoV-2 Spike RBD protein fragments (WT / Alpha / Beta / Gamma / Delta / Omicron) were conjugated to 6 fluorochrome-encoded microspheres respectively, indicated in Table 1. The Anti-SARS-CoV-2 IgG Antibody in blood specimens was bound to the RBD encapsulated 6-plex beads, and then detected by PE-conjugated anti-mouse IgG detection antibody, forming bead-analyte-detection antibody sandwiches. The intensity of PE fluorescence was assessed by flow cytometry at wavelength of 575 nm approximately, in proportion to the Anti-SARS-CoV-2 IgG titer in blood specimens. The intensity of APC fluorescence was applied to classify bead populations, at wavelength of 670 nm approximately.

*Optional: If there is vacuum manifold for 96-Well plates, 96-Well Filter Plate (ACROBiosystems, cat#FCM-B01M) is prepared.
 

活性(Bioactivity)-FACS

Biotinylated Human FACS

A representative datapoint showing single bead population in P1 gate (left), SARS-CoV-2 variant immobilized beads classified by APC channel (middle, P2 ~ P7 gate), and measured fluorescence signal for each population in PE channel (right). Data was generated on BD FACSLyricTM Flow Cytometer, equipped with blue laser (488 nm) and red laser (640 nm).

Spike RBD FACS

A 4-parameter logistic model fitting curve was plotted on mouse SARS-CoV-2 Variants total IgG 6-plex Panel. Immobilized SARS-CoV-2 variant RBD proteins bind with a serial dilution of potent and broad antibody calibrator, ranging from 16.5 ng/ml to 4160 ng/ml (QC tested). EC50 values indicate the concentration at which 50% of calibrator were bound.

背景(Background):Spike RBD

Spike,S protein RBD,Spike glycoprotein Receptor-binding domain,S glycoprotein RBD,Spike protein RBD
The newly identified Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) poses continual threat to human health due to rapid transmission worldwide. The deleloped of effcient treatment agaginst SARS-CoV-2 is an emergent need for global pubic heath,and it is necessary to develop SARS-CoV-2 inhibitors, such as vaccines, therapeutic antibodies and small molecule compounds against SARS-CoV-2. Therefore, it is helpful to develop the SARS-CoV-2 (WT) Inhibitor Screening Kit (Spike RBD) to test SARS-CoV-2 inhibitors.

 

前沿进展

 
 
货号/价格
文档
联系电话:
+86 400-682-2521(全国)
010-53681107(北京)
021-50850665(上海)
运输方式
订单邮箱:
order.cn@acrobiosystems.com
技术支持邮箱:
tech.cn@acrobiosystems.com
前沿进展
点击查看详细

消息提示

请输入您的联系方式,再点击提交!

确定