登录 | 注册    关注公众号  
微信公众号
搜索
 >  Protein>Serum Albumin >HSA-H82E3

Biotinylated Human Serum Albumin Protein, His,Avitag™ (MALS verified)

分子别名(Synonym)

Serum albumin,ALB,Alb

表达区间及表达系统(Source)

Biotinylated Human Serum Albumin, His,Avitag (HSA-H82E3) is expressed from human 293 cells (HEK293). It contains AA Asp 25 - Leu 609 (Accession # P02768-1).

Predicted N-terminus: Asp 25

Request for sequence

蛋白结构(Molecular Characterization)

Serum Albumin Structure

This protein carries a polyhistidine tag at the C-terminus, followed by an Avi tag (Avitag™)

The protein has a calculated MW of 70.2 kDa. The protein migrates as 70 kDa under reducing (R) condition (SDS-PAGE) due to glycosylation.

标记(Labeling)

Biotinylation of this product is performed using Avitag™ technology. Briefly, the single lysine residue in the Avitag is enzymatically labeled with biotin.

蛋白标记度(Protein Ratio)

Passed as determined by the HABA assay / binding ELISA.

内毒素(Endotoxin)

Less than 1.0 EU per μg by the LAL method.

纯度(Purity)

>95% as determined by SDS-PAGE.

>90% as determined by SEC-MALS.

制剂(Formulation)

Lyophilized from 0.22 μm filtered solution in PBS, pH7.4 with trehalose as protectant.

Contact us for customized product form or formulation.

重构方法(Reconstitution)

Please see Certificate of Analysis for specific instructions.

For best performance, we strongly recommend you to follow the reconstitution protocol provided in the CoA.

存储(Storage)

For long term storage, the product should be stored at lyophilized state at -20°C or lower.

Please avoid repeated freeze-thaw cycles.

This product is stable after storage at:

  1. -20°C to -70°C for 12 months in lyophilized state;
  2. -70°C for 3 months under sterile conditions after reconstitution.

质量管理控制体系(QMS)

  1. 质量管理体系(ISO, GMP)
  2. 质量优势
  3. 质控流程
 

电泳(SDS-PAGE)

Serum Albumin SDS-PAGE

Biotinylated Human Serum Albumin, His,Avitag on SDS-PAGE under reducing (R) condition. The gel was stained with Coomassie Blue. The purity of the protein is greater than 95%.

SEC-MALS

Serum Albumin SEC-MALS

The purity of Biotinylated Human Serum Albumin, His,Avitag (Cat. No. HSA-H82E3) is more than 90% and the molecular weight of this protein is around 64-80 kDa verified by SEC-MALS.

Report

 

活性(Bioactivity)-BLI

Serum Albumin BLI

Loaded Biotinylated Human Serum Albumin, His,Avitag (Cat. No. HSA-H82E3) on SA Biosensor, can bind Human FCGRT&B2M Heterodimer Protein, His Tag&Strep II Tag (Cat. No. FCM-H5286) with an affinity constant of 0.641 μM as determined in BLI assay (ForteBio Octet Red96e) (QC tested).

Protocol

 
评论(3)
  1. 203XXXXXXX
  2. 2人赞
  3. My biotinylated Human Serum Albumin came in a timely manner, which was crucial for my experiment to run so I could meet deadlines. I was happy to find out that AcroBiosystems offered a biotinylated product that was greater than 95% purity. I ordered the 25 ug HSA which worked well for my purposes for SPR by the Biacore T200. My shipment arrived perfectly and it was packaged safely. I would order from this company again for their quick processing time and quality of products.
  4. 2022-3-21
  1. 183XXXXXXX9
  2. 1人赞
  3. 该蛋白是生物素化的修饰蛋白,我们利用生物素-链霉亲和素系统的高特异性和高灵敏度的结合特性,将生物素化的HSA蛋白与链霉亲和素产品联合应用于ELISA实验,与非生物素体系相比,检测速度更快、结合能力更强、非特异背景更低。已经使用该蛋白进行了一年多的ELISA实验,获得很好的实验结果。此外,ACRO的发货速度和服务态度很赞,会继续使用该蛋白进行产品的稳定性能研究。
  4. 2023-10-7
  1. 183XXXXXXX9
  2. 0人赞
  3. 该蛋白属于生物素化蛋白,具有高特异性和高灵敏度的结合特性,我们主要将该生物素化蛋白应用于Binding ELISA实验,与非生物素体系相比,检测速度更快、结合能力更强、非特异背景更低。
  4. 2023-2-14
 
ACRO质量管理体系
 
 

背景(Background)

serum albumin (SA) is also known as ALB, which is the main protein of plasma and has a good binding capacity for water,Ca2+,Na+,K+,fatty acids,hormones, bilirubin and drugs.The main function of SA is the regulation of the colloidal osmotic pressure of blood. As Major zinc transporter in plasma, SA typically binds about 80% of all plasma zinc. A variant structure of albumin could lead to increased binding of zinc resulting in an asymptomatic augmentation of zinc concentration in the blood. Defects in serum albumin can cause familial dysalbuminemic hyperthyroxinemia which is a form of euthyroid hyperthyroxinemia that is due to increased affinity of serum albumin for T4. It is the most common cause of inherited euthyroid hyperthyroxinemia in Caucasian population.

 

前沿进展

Enhanced Protein Separation Performance of Cellulose Acetate Membranes Modified with Covalent Organic Frameworks
Shao, Liu, Tao et al
Membranes (Basel) (2025) 15 (3)
Abstract: As a porous crystalline material, covalent organic frameworks (COFs) have attracted significant attention due to their extraordinary features, such as an ordered pore structure and excellent stability. Synthesized through the aldehyde amine condensation reaction, TpPa-1 COFs (Triformylphloroglucinol-p-Phenylenediamine-1 COFs) were blended with cellulose acetate (CA) to form a casting solution. The TpPa-1 COF/CA ultrafiltration membrane was then prepared using the non-solvent-induced phase inversion (NIPS) method. The influence of TpPa-1 COFs content on the hydrophilicity, stability and filtration performance of the modified membrane was studied. Due to the hydrophilic groups in TpPa-1 COFs and the network structure formed by covalent bonds, the modified CA membranes exhibited higher hydrophilicity and lower protein adsorption compared with the pristine CA membrane. The porous crystalline structure of TpPa-1 COFs increased the water permeation path in the CA membrane, improving the permeability of the modified membrane while maintaining an outstanding bovine serum albumin (BSA) rejection. Furthermore, the addition of TpPa-1 COFs reduced protein adsorption on the CA membrane and overcame the trade-off between permeability and selectivity in CA membrane bioseparation applications. This approach provides a sustainable method for enhancing membrane performance while enhancing the application of membranes in protein purification.
A Portable Smartphone-Based 3D-Printed Biosensing Platform for Kidney Function Biomarker Quantification
Palekar, Kalambe, Kalambe et al
Biosensors (Basel) (2025) 15 (3)
Abstract: Detecting kidney function biomarkers is critical for the early diagnosis of kidney diseases and monitoring treatment efficacy. In this work, a portable, 3D-printed colorimetric sensor platform was developed to detect key kidney biomarkers: uric acid, creatinine, and albumin. The platform features a 3D-printed enclosure with integrated diffused LED lighting to ensure a controlled environment for image acquisition. A disposable 3D-printed flow cell holds samples, ensuring precision and minimizing contamination. The sensor relies on colorimetric analysis, where a reagent reacts with blood serum to produce a color shift proportional to the biomarker concentration. Using a smartphone, the color change is captured, and RGB values are normalized to calculate concentrations based on the Beer-Lambert Law. The system adapts to variations in smartphones, reagent brands, and lighting conditions through an adaptive calibration algorithm, ensuring flexibility and accuracy. The sensor demonstrated good linear detection ranges for uric acid (1-30 mg/dL), creatinine (0.1-20 mg/dL), and albumin (0.1-8 g/dL), with detection limits of 1.15 mg/dL, 0.15 mg/dL, and 0.11 g/dL, respectively. These results correlated well with commercial biochemistry analyzers. Additionally, an Android application was developed to handle image processing and database management, providing a user-friendly interface for real-time blood analysis. This portable, cost-effective platform shows significant potential for point-of-care diagnostics and remote health monitoring.
An Antimicrobial and Antifibrotic Coating for Implantable Biosensors
Wareham-Mathiassen, Jolly, Radha Shanmugam et al
Biosensors (Basel) (2025) 15 (3)
Abstract: Biofouling and foreign body responses have deleterious effects on the functionality and longevity of implantable biosensors, seriously impeding their implementation for long-term monitoring. Here, we describe a nanocomposite coating composed of a cross-linked lattice of bovine serum albumin and pentaamine-functionalized reduced graphene that is covalently coupled to antibody ligands for analyte detection as well as antibiotic drugs (gentamicin or ceftriaxone), which actively combats biofouling while retaining high electroconductivity and excellent electrochemical immunosensor behavior. Sensors overlaid with this coating inhibit the proliferation of Pseudomonas aeruginosa bacteria and adhesion of primary human fibroblasts while not having any significant effects on fibroblast viability or on the immune function of primary human monocytes. Under these conditions, the sensor maintains its electrochemical stability for at least 3 weeks after exposure to soluble proteins that interfere with the activity of uncoated sensors. Proof-of-concept for the coating's applicability is demonstrated by integrating the antimicrobial coating within an immunosensor and demonstrating the detection of cytokines in both culture medium and complex human plasma. This new coating technology holds the potential to substantially increase the lifespan of implanted biosensors and widen their application areas, potentially enabling continuous monitoring of analytes in complex biofluids for weeks in vivo.
The Severity of Carotid Calcifications, but Not Fibroblast Growth Factor 23, Is Associated with Mortality in Hemodialysis: A Single Center Experience
Moldovan
Diseases (2025) 13 (3)
Abstract: The study goal was to assess the mortality effect of carotid vascular calcifications (VC), of fibroblast growth factor 23 (FGF-23), mineral markers, and comorbidities in hemodialysis (HD) patients.The influence of carotid VC severity, FGF-23, laboratory markers, clinical features, and comorbidities on mortality was analyzed in a cohort of 88 HD patients. The follow-up period lasted 8 years. The cut-off value for carotid VC was 4 for all-cause and cardiovascular mortality.Carotid VC, diabetes, low serum albumin, high serum C-reactive protein (CRP), and the presence of cardiovascular diseases are associated with all-cause and cardiovascular mortality. Carotid VC score over 4 was an independent predictor of all-cause and cardiovascular mortality, along with diabetes, low albumin, and high CRP. FGF-23 was not found to be predictable for the study outcomes.The study documented in a cohort of patients prevalent in chronic HD that carotid VC predicts all-cause and cardiovascular mortality at 8 years and improves risk stratification, but FGF-23 is not associated with mortality. Other risk factors for all-cause and cardiovascular mortality were diabetes, inflammation, and malnutrition. However, future efforts are needed to assess whether a risk-based approach, including VC screening, improves survival.
Showing 1-4 of 154922 papers.
Powered by BizGenius
 
 
货号/价格
产品推荐
文档
联系电话:
+86 400-682-2521(全国)
010-53681107(北京)
021-50850665(上海)
运输方式
订单邮箱:
order.cn@acrobiosystems.com
技术支持邮箱:
tech.cn@acrobiosystems.com
Serum Albumin靶点信息
英文全称:Serum albumin
中文全称:血清白蛋白
种类:Homo sapiens
上市药物数量:17详情
临床药物数量:13详情
最高研发阶段:批准上市
查看更多信息
前沿进展
点击查看详细

消息提示

请输入您的联系方式,再点击提交!

确定