ID | Components | Size |
CRS014-C01 | Pre-coated Human CD28 Microplate | 1 plate |
CRS014-C02 | Anti-CD28 Antibody Standard | 20 μg |
CRS014-C03 | HRP-Goat anti-Mouse IgG | 10 μg |
CRS014-C04 | 10xWashing Buffer | 50 mL |
CRS014-C05 | 2xDilution Buffer | 50 mL |
CRS014-C06 | Substrate Solution | 12 mL |
CRS014-C07 | Stop Solution | 7 mL |
背景(Background)
Similar to CD3 antibody, CD28 antibodies also can be used to stimulate the proliferation and activation of T cells in CIK cell therapy. Under the cooperation of other cytokines, such as IL2 and IL1a, CIK cells with rapid proliferation, high tumoricidal activity, broad tumor killing spectrum and non-MHC-restricted tumor killing characteristics are generated, which has significant effects on the treatment of cancer, chronic leukemia, liver disease and neurological diseases. Obviously, It is necessary to control the residues of raw materials in the final cell therapy products.
应用说明(Application)
The kit is developed for the detection of anti-CD28 antibody in Bioprocess manufacturing applications. It is used as a tool to aid in routine quality control of in-process streams as well as final product.
It is for research use only.
重构方法(Reconstitution)
Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.
存储(Storage)
Unopened kit should be stored at 2°C -8°C upon receiving.
Find the expiration date on the outside packaging and do not use reagents past their expiration date.
The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
原理(Assay Principles)
This assay kit employs a standard indirect-ELISA format, providing a rapid detection of Anti-CD28 antibodies. The kit consists of Pre-coated Human CD28 Microplate and Anti-CD28 Antibody Standard and HRP-Anti-Mouse IgG secondary antibody and related buffer.
Your experiment will include 5 simple steps:
a) All reagents were returned to room temperature(20℃-25℃) before use.
b) Add your sample to the plate, take the Anti-CD28 Antibody as standard sample. The samples and standard sample are diluted by Dilution Buffer.
c) Wash the plate and add a diluted HRP-Goat anti-Mouse IgG to the plate. The diluted by Dilution Buffer.
d) Wash the plate and add TMB.
e) Stop the substrate reaction by add diluted acid. Absorbance (OD) is calculate as the absorbance at 450 nm minus the absorbance at 630 nm to remove background prior to statistical analysis. The OD Value reflects the amount of Antibody bound.
典型数据-Typical Data Please refer to Ds document for the assay protocol.
Detection of Monoclonal Anti-CD28 Antibody titer by indirect-ELISA Assay.
Immobilized Human CD28 can bind Anti-CD28 Antibody. Detection was performed using HRP-Goat anti-Mouse IgG with sensitivity of 0.16 ng/mL (QC tested).