- Rapid - Results can be obtained within 90 minutes.
- Reference Standard Traceability - The reference standard is traceable to the National Standard USP (Cat # 1076192).
- Rigorous Method Validation - Validation reports compliant with ICH guidelines can be provided upon request.
- High Sensitivity - Sensitivity for Bovine Serum Albumin (BSA) is < 0.5 ng/mL.
- Strong Specificity - No cross-reactivity with non-target proteins.
- Excellent Buffer Compatibility - Compatible with a wide range of buffer systems.
产品描述(Product Details)
Assay Type | Sandwich-ELISA |
Analyte | BSA (Bovine serum albumin) |
Traceability | USP (Cat # 1076192) |
Format | 96T(8×12 strips) |
Regulatory Status | RUO |
Sensitivity | <0.5ng/mL |
Standard Curve Range | 0.5ng/mL-40.5ng/mL |
Assay Time | 1.5 hr |
Suitable Sample Type | For the quantitative determination of BSA (Bovine serum albumin) |
Sample volume | 50 μL |
背景(Background)
Bovine serum, primarily composed of Bovine Serum Albumin (BSA), is widely used in biological product manufacturing. However, as a heterologous protein, BSA poses risks such as immunopathological reactions, allergies, and immunogenicity, potentially compromising product safety and efficacy.
To address this, global regulatory authorities enforce strict quality control measures. These include optimizing production processes, validating purification methods, and employing sensitive analytical techniques to minimize BSA residues to acceptable levels. Such controls are essential to ensure the safety, efficacy, and regulatory compliance of biological products.
应用说明(Application)
The kit is developed for the detection and quantitative determination of BSA in cell culture supernates.The standard BSA has been calibrated against USP standard (cat # 1076192) for accurate assay result.
It is for research use only.
存储(Storage)
1. Unopened kit should be stored at 2℃-8℃ upon receiving.
2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.
3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
组分(Materials Provided)
ID | Components | Size |
RES98-C01 | Pre-Coated Anti-BSA Antibody Microplate | 1 plate(8×12 strips) |
RES98-C02A | BSA Standard (200ng/mL) | 500μL |
RES98-C02B | BSA Standard 5 (40.5ng/mL) | 500μL |
RES98-C02C | BSA Standard4 (13.5ng/mL) | 500μL |
RES98-C02D | BSA Standard 3 (4.5ng/mL) | 500μL |
RES98-C02E | BSA Standard 2 (1.5ng/mL) | 500μL |
RES98-C02F | BSA Standard 1 (0.5ng/mL) | 500μL |
RES98-C02G | BSA Standard 0 (0ng/mL) | 500μL |
RES98-C03 | HRP-Anti-BSA Antibody | 100μL |
RES98-C04 | 1×Sample Dilution Buffer | 50mL×2 |
RES98-C05 | 20×Washing Buffer | 25mL |
RES98-C06 | Substrate Solution | 12mL |
RES98-C07 | Stop Solution | 8mL |
典型数据-Typical Data Please refer to DS document for the assay protocol.

Detection of BSA (Bovine Serum Albumin) by ELISA Assay.
Immobilized Anti-BSA Antibody can bind BSA (Bovine Serum Albumin) Detection was performed using HRP-Anti- BSA Antibody with sensitivity of 0.5 ng/mL (QC tested). For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.
验证(Validation)
稀释线性(Dilution Linearity)
To assess the linearity of the assay, samples spiked with high concentrations of BSA were serially diluted with calibrator diluent to produce samples with values within the dynamic range of the assay.
批内差异(Intra-Assay Statistics)
Three samples of known concentration were tested ten times on one plate to assess intra-assay precision , Intra-Assay Precision CV≤15%.
批间差异(Inter-Assay Statistics)
Three samples of known concentration were tested in three separate assays to assess inter-assay precision, Inter-Assay Precision CV≤15%.
准确度(Accuracy)
Five samples of known concentration were tested ten times to assess Accuracy , Accuracy recovery rate 80-120%.
干扰效应(Interference effect)
Verify potential matrix effects by adding different levels of specific buffers to the sample buffer. For specific buffers, it is recommended that you verify recovery to determine the optimal dilution ratio.
专属性(Specificity)
High, medium and low concentrations of BSA were added to Human serum (v/v 1%), Mouse serum (v/v 2.5%), Human Serum Albumin (1.25mg/mL) and Rabbit serum (v/v 10%), the recovery rate of BSA was used as the specific validation index.
High, medium and low concentrations of BSA were added to MDCK Cell, HEK293 Cell, CHO Cell , T Cell and VERO Cell, the recovery rate of BSA was used as the specific validation index.
背景(Background):BSA
BSA